目前要做的架構是如上圖
雖然目前看起來是能動,但初次設定SAN SWITCH不確定有沒有做錯
想請問一下各位這樣子有沒有問題?
另外也不懂Dell原廠建議把virtual WWNs跟physical WWNs各設定一組Zone的用途?
參考資料1
參考資料2
feature npiv
vsan database
vsan 100
vsan 100 interface fc1/1
vsan 100 interface fc1/2
vsan 100 interface fc1/3
vsan 100 interface fc1/4
vsan 100 interface fc1/5
zone name Dell-vWWNs vsan 100
member pwwn "vWWN-A"
member pwwn "vWWN-B"
zone name Dell-pWWNs vsan 100
member pwwn "pWWN-A"
member pwwn "pWWN-B"
zone name ServerA-Dell vsan 100
member pwwn "vWWN-A"
member pwwn "vWWN-B"
member pwwn "SA-WWN"
zone name ServerB-Dell vsan 100
member pwwn "vWWN-A"
member pwwn "vWWN-B"
member pwwn "SB-WWN"
zone name ServerAB-HP vsan 100
member pwwn "SA-WWN"
member pwwn "SB-WWN"
member pwwn "HP-WWN"
zoneset name zoneset1 vsan 100
member "Dell-vWWNs"
member "Dell-pWWNs"
member "ServerA-Dell"
member "ServerB-Dell"
member "ServerAB-HP"
zoneset activate zoneset1 vsan 100
有另一台上線運作中的同型號的SAN Switch,看Config好像只是建VSAN把Port指派過去而已
沒設定Zone也沒設定Zoneset。
但新的這台照那樣做卻通不了