Advance Member
|
昨天某次開機後
MSM跳出訊息顯示RAID的其中一個硬碟突然離線
我把她重建後做了Consistency Check
結果跳出錯誤訊息
這些訊息是啥意思
代表硬碟壞軌?還是?
ID = 58
SEQUENCE NUMBER = 61839
TIME = 11-12-2013 01:25:10
LOCALIZED MESSAGE = Controller ID: 0 Consistency Check done on VD: 1
ID = 113
SEQUENCE NUMBER = 61735
TIME = 11-12-2013 00:57:34
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61734
TIME = 11-12-2013 00:57:34
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x02 0x58 0x26 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61733
TIME = 11-12-2013 00:57:34
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61732
TIME = 11-12-2013 00:57:34
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x02 0x58 0x26 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61729
TIME = 11-12-2013 00:56:53
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61728
TIME = 11-12-2013 00:56:43
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61727
TIME = 11-12-2013 00:56:42
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61726
TIME = 11-12-2013 00:56:42
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x02 0x00 0x5e 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61725
TIME = 11-12-2013 00:56:33
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Unknown Sense Code, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x11 0x02 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61724
TIME = 11-12-2013 00:56:33
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Power on occurred, CDB = 0x4d 0x00 0x40 0x00 0x00 0x00 0x00 0x00 0xfc 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x01 0x01 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61722
TIME = 11-12-2013 00:56:23
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x01 0xda 0xdd 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61721
TIME = 11-12-2013 00:56:23
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61720
TIME = 11-12-2013 00:56:23
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x01 0xda 0xdd 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61718
TIME = 11-12-2013 00:55:53
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61717
TIME = 11-12-2013 00:55:43
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61716
TIME = 11-12-2013 00:55:43
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x01 0xb0 0x09 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61715
TIME = 11-12-2013 00:55:43
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61714
TIME = 11-12-2013 00:55:43
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x01 0xb0 0x09 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61712
TIME = 11-12-2013 00:55:23
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x01 0x84 0xb2 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61711
TIME = 11-12-2013 00:55:23
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61710
TIME = 11-12-2013 00:55:23
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x01 0x84 0xb2 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61708
TIME = 11-12-2013 00:55:03
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x01 0x58 0xe5 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61707
TIME = 11-12-2013 00:55:03
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61706
TIME = 11-12-2013 00:55:03
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x01 0x58 0xe5 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61704
TIME = 11-12-2013 00:54:30
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61703
TIME = 11-12-2013 00:54:20
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61702
TIME = 11-12-2013 00:54:20
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x01 0x1b 0x1f 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61701
TIME = 11-12-2013 00:54:20
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61700
TIME = 11-12-2013 00:54:20
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x01 0x1b 0x1f 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61698
TIME = 11-12-2013 00:53:50
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61697
TIME = 11-12-2013 00:53:40
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61696
TIME = 11-12-2013 00:53:40
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0xf0 0xe3 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61695
TIME = 11-12-2013 00:53:40
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61694
TIME = 11-12-2013 00:53:40
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0xf0 0xe3 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61692
TIME = 11-12-2013 00:53:14
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61691
TIME = 11-12-2013 00:53:04
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61690
TIME = 11-12-2013 00:53:04
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0xdc 0x02 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61689
TIME = 11-12-2013 00:53:04
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61688
TIME = 11-12-2013 00:53:04
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0xdc 0x02 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61686
TIME = 11-12-2013 00:52:48
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0xc7 0x83 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61685
TIME = 11-12-2013 00:52:48
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61684
TIME = 11-12-2013 00:52:48
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0xc7 0x83 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61683
TIME = 11-12-2013 00:52:34
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0xbd 0xfb 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61682
TIME = 11-12-2013 00:52:34
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61681
TIME = 11-12-2013 00:52:34
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0xbd 0xfb 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61679
TIME = 11-12-2013 00:52:08
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61678
TIME = 11-12-2013 00:52:08
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0xac 0x77 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61677
TIME = 11-12-2013 00:52:08
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61676
TIME = 11-12-2013 00:52:08
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0xac 0x77 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61675
TIME = 11-12-2013 00:51:43
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61674
TIME = 11-12-2013 00:51:43
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x9f 0x93 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61673
TIME = 11-12-2013 00:51:43
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61672
TIME = 11-12-2013 00:51:43
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x9f 0x93 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61671
TIME = 11-12-2013 00:51:16
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61670
TIME = 11-12-2013 00:51:06
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61669
TIME = 11-12-2013 00:51:06
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x9d 0x8c 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61668
TIME = 11-12-2013 00:51:06
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61667
TIME = 11-12-2013 00:51:06
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x9d 0x8c 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61665
TIME = 11-12-2013 00:50:39
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61664
TIME = 11-12-2013 00:50:29
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61663
TIME = 11-12-2013 00:50:29
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x85 0xf8 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61662
TIME = 11-12-2013 00:50:29
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61661
TIME = 11-12-2013 00:50:29
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x85 0xf8 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61659
TIME = 11-12-2013 00:50:02
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61658
TIME = 11-12-2013 00:49:52
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61657
TIME = 11-12-2013 00:49:52
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x70 0x5e 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61656
TIME = 11-12-2013 00:49:52
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61655
TIME = 11-12-2013 00:49:52
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x70 0x5e 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61653
TIME = 11-12-2013 00:49:26
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61652
TIME = 11-12-2013 00:49:16
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61651
TIME = 11-12-2013 00:49:16
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x5d 0x23 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61650
TIME = 11-12-2013 00:49:16
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61649
TIME = 11-12-2013 00:49:16
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x5d 0x23 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61647
TIME = 11-12-2013 00:49:01
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x51 0x21 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61646
TIME = 11-12-2013 00:49:01
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61645
TIME = 11-12-2013 00:49:01
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x51 0x21 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61644
TIME = 11-12-2013 00:48:47
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x4b 0x10 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61643
TIME = 11-12-2013 00:48:47
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61642
TIME = 11-12-2013 00:48:47
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x4b 0x10 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61641
TIME = 11-12-2013 00:48:24
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61640
TIME = 11-12-2013 00:48:14
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61639
TIME = 11-12-2013 00:48:14
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x48 0xeb 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61638
TIME = 11-12-2013 00:48:14
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61637
TIME = 11-12-2013 00:48:14
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x48 0xeb 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61636
TIME = 11-12-2013 00:48:00
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x43 0x1d 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61635
TIME = 11-12-2013 00:48:00
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61634
TIME = 11-12-2013 00:48:00
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x43 0x1d 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61632
TIME = 11-12-2013 00:47:46
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x3d 0xb7 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61631
TIME = 11-12-2013 00:47:46
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61630
TIME = 11-12-2013 00:47:46
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x3d 0xb7 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61629
TIME = 11-12-2013 00:47:22
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61628
TIME = 11-12-2013 00:47:12
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61627
TIME = 11-12-2013 00:47:12
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x35 0xa0 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61626
TIME = 11-12-2013 00:47:12
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61625
TIME = 11-12-2013 00:47:12
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x35 0xa0 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61624
TIME = 11-12-2013 00:46:59
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x32 0x7f 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61623
TIME = 11-12-2013 00:46:59
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61622
TIME = 11-12-2013 00:46:59
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x32 0x7f 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61620
TIME = 11-12-2013 00:46:35
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61619
TIME = 11-12-2013 00:46:25
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61618
TIME = 11-12-2013 00:46:25
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x2b 0x4e 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61617
TIME = 11-12-2013 00:46:25
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61616
TIME = 11-12-2013 00:46:25
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x2b 0x4e 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61615
TIME = 11-12-2013 00:45:58
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61614
TIME = 11-12-2013 00:45:48
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61613
TIME = 11-12-2013 00:45:48
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x27 0xd7 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61612
TIME = 11-12-2013 00:45:48
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61611
TIME = 11-12-2013 00:45:48
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x27 0xd7 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61610
TIME = 11-12-2013 00:45:34
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x21 0xa2 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61609
TIME = 11-12-2013 00:45:34
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61608
TIME = 11-12-2013 00:45:34
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x21 0xa2 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61607
TIME = 11-12-2013 00:45:11
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61606
TIME = 11-12-2013 00:45:11
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Power on occurred, CDB = 0x28 0x00 0x00 0x20 0xc6 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x01 0x01 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61605
TIME = 11-12-2013 00:45:10
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x20 0xa7 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61604
TIME = 11-12-2013 00:45:10
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61603
TIME = 11-12-2013 00:45:10
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x20 0xa7 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61602
TIME = 11-12-2013 00:44:57
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x1e 0xd2 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61601
TIME = 11-12-2013 00:44:57
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61600
TIME = 11-12-2013 00:44:57
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x1e 0xd2 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61599
TIME = 11-12-2013 00:44:34
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61598
TIME = 11-12-2013 00:44:24
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61597
TIME = 11-12-2013 00:44:24
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x1d 0x0f 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61596
TIME = 11-12-2013 00:44:24
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61595
TIME = 11-12-2013 00:44:24
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x1d 0x0f 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61594
TIME = 11-12-2013 00:44:10
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x16 0xec 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61593
TIME = 11-12-2013 00:44:10
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61592
TIME = 11-12-2013 00:44:10
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x16 0xec 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61590
TIME = 11-12-2013 00:43:46
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61589
TIME = 11-12-2013 00:43:36
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61588
TIME = 11-12-2013 00:43:36
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x13 0x10 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61587
TIME = 11-12-2013 00:43:36
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61586
TIME = 11-12-2013 00:43:36
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x13 0x10 0x80 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61585
TIME = 11-12-2013 00:43:22
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x0c 0x3a 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61584
TIME = 11-12-2013 00:43:22
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61583
TIME = 11-12-2013 00:43:22
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x0c 0x3a 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61582
TIME = 11-12-2013 00:43:09
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x0a 0xe3 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61581
TIME = 11-12-2013 00:43:09
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61580
TIME = 11-12-2013 00:43:09
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x0a 0xe3 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61579
TIME = 11-12-2013 00:42:46
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61578
TIME = 11-12-2013 00:42:46
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Power on occurred, CDB = 0x28 0x00 0x00 0x08 0xdd 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x01 0x01 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61577
TIME = 11-12-2013 00:42:45
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x08 0x2d 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61576
TIME = 11-12-2013 00:42:45
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61575
TIME = 11-12-2013 00:42:45
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x08 0x2d 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61574
TIME = 11-12-2013 00:42:21
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61573
TIME = 11-12-2013 00:42:11
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0Logical unit is in process of becoming ready, CDB = 0x00 0x00 0x00 0x00 0x00 0x00 , Sense = 0x70 0x00 0x02 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x04 0x01 0x00 0x00 0x00 0x00
ID = 113
SEQUENCE NUMBER = 61572
TIME = 11-12-2013 00:42:11
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x04 0xc4 0x00 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61571
TIME = 11-12-2013 00:42:11
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 267
SEQUENCE NUMBER = 61570
TIME = 11-12-2013 00:42:11
LOCALIZED MESSAGE = Controller ID: 0 Command timeout on PD: PD = -:-:0No addtional sense information, CDB = 0x28 0x00 0x00 0x04 0xc4 0x00 0x00 0x00 0x80 0x00 , Sense = , Path = 0x5000C50059756601
ID = 113
SEQUENCE NUMBER = 61569
TIME = 11-12-2013 00:41:57
LOCALIZED MESSAGE = Controller ID: 0 Unexpected sense: PD = -:-:0SCSI bus reset occurred, CDB = 0x28 0x00 0x00 0x00 0x35 0x80 0x00 0x00 0x80 0x00 , Sense = 0x70 0x00 0x06 0x00 0x00 0x00 0x00 0x0a 0x00 0x00 0x00 0x00 0x29 0x02 0x02 0x00 0x00 0x00
ID = 268
SEQUENCE NUMBER = 61568
TIME = 11-12-2013 00:41:57
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD = -:-:0, Critical = 3, Path = 0x5000C50059756601
ID = 66
SEQUENCE NUMBER = 61566
TIME = 11-12-2013 00:41:44
LOCALIZED MESSAGE = Controller ID: 0 Consistency Check started on VD: 1
|